Ceramic Tube Directional X-Ray Flaw Detector is made of directional ceramic x ray tube and HV coil . It has advantage of small dimension and weight than glass tube , also working life is longer . Its model contains 160kv-350kv, max.penetration reach 70mm.
Features :
1. High degree aluminum radiator to improve 30% heat radiation.
2. Portable design, light weight and easy operation.
3. SF6 gas insulator, grounded-anode design to keep the operator safety.
4. Strictly follow 1:1 work and rest radio,avoid the interference by voltage changing.
5. Time-delayed function to reserve enough time for operators moving to safety distance.
6. Fault shooting automatically, pressure indication to make easy operating for the operator.
Beam Angle | Model | Tube Voltage (KV) | Capacity (KW) | Focus Size (mm) | Max. Penetrate A3 steel (mm) | X-ray Generator Weight (kg) |
40° | XXG-1605 | 35-160 | >1.5 | 1.5*1.5 | 20 | 18 |
XXG-2005 | 50-200 | >2.5 | 2.0*2.0 | 29 | 24 | |
XXG-2505 | 80-250 | >2.5 | 2.0*2.0 | 39 | 30 | |
XXG-3005 | 130-300 | >3.0 | 2.5*2.5 | 49 | 35 | |
XXG-3505 Max.10 min shoot | 180-350 | >3.5 | 2.5*2.5 | 70 | 38 | |
Tube Current | 5mA | |||||
Power Supply | AC220V ±10% 50HZ | |||||
Insulating Material | SF6 gas | |||||
Working Temperature | -25°C~ 40°C | |||||
Relative Humidity | ≤85% | |||||
Working Conditions
| 1. Focus : 600mm 2. Exposure time: 5 min. 3. Film: KODAK , intensified by double lead foil. 4. Treatment in the darkroom: Temp. 20 ±2ºC, 5 min. | |||||
Safe Pressure | 0.35 ~ 0.50 Mpa (Operation will be prohibited in the case less than 0.35 Mpa) |
List
No. | Item | Qty |
1 | Ceramic Tube Directional X Ray Generator | 1 |
2 | ZY-2000/ZY-3000/ZY-4000 Control Unit | 1 |
3 | Connecting cable | 1 |
4 | Power cable (2cores) 10m | 1 |
5 | Earthing wire 5m | 1 |
6 | Fuse | 5 |
7 | Bag | 1 |
8 | Operation Manual | 1 |